PadPuls M2C

PadPuls M2C | Relay Australia | M-Bus | Automation Industries

The 2-channel pulse adaptor PadPuls M2C allows the use of up to 2 meters with pulse output as M -Bus slaves. So for example, data from a simple water or electricity meter can central be read out by M-Bus. Optionally the user can activate a tariff function, by which energy or volume pulses can be accumulated in separate meter readings for primary and secondary tariffs.

  • Two separated pulse inputs

  • Safe detection of up to 16 pulses per second at each input

  • Pulse debouncing

  • Pulse value free adjustable

  • Unit free selectable (e.g. Wh, kWh, MWh, kJ, m3, l,...)

  • Counter length: 8 decimal digits

  • Due-date function with integrated realtime clock

  • Yearly due-date and 15 monthly values (optional)

  • M-Bus protocol according to EN13757-2- and -3

  • Fully parameterizable by M-Bus, including overwrite protection

  • Transmission rate: 300, 2400 and 9600 baud with auto baud detection

  • Fully operable in case of M-Bus failure by integrated battery

  • Dimensions W x H x D: 93 x 51 x 58 mm

  • Mounted on DIN rail

  • Two battery options available

The devices of the PadPuls M2 series adapt up to two conventional meters with pulse output to a M-Bus system. The two counter inputs are nearly free parameterizable and fit in already existing installations.
Optionally the user can activate a tariff function, by which energy or volume pulses can be accumulated in separate meter readings for primary and secondary tariffs. O one pulse signal and one changeover signal for the tariff are required, for example out of a ripple control receiver from the electricity supplier.
The integrated battery ensures that the impulse adaptor is fully operable, even if the M-Bus network fails. Additional security is provided by the periodic saving of the meter readings in nonvolatile memory.

PadPuls M2C Flow | Relay Australia | M-Bus | Automation Industries

Technical Data

Power supply

Remote supply by M-Bus with automatic switch to battery on bus fail

Bus operation

max. 1.5mA (1 unit load), no load of battery

Battery lifetime 0,23Ah

10 years at max. 80 failure days p.a. (changeable coin type battery)

Batterie lifetime 1,80Ah

10 years at max. 250 failure days p.a.

Operating temperature

0..55 °C

Battery expectancy

Current draw typ. 8μA

Pulse inputs

2, individually programmable

Potential-free contact

Contact voltage

2,5V .. 3,6V

Contact current

30μA

Cable pulse generator

max. 10m

Debouncing time

5ms

Potential

free of potential

Resistance

open > 1MΩ, closed < 2kΩ

Contact duration

min. 30ms

Temperature range

Pulse frequency

max. 14 Hz

Tariff signal

potential free (data see above)

Floating contact

S0 according to DIN43864

M-Bus protocol

according to EN13757-2 and -3

Baudrates

300, 2400 and 9600 baud (automatic detection)

Mounting

DIN rail

Protective class

IP40

Dimensions

WxHxD:93x51x58mm

Transmission rate

Addressing

Card IM001

Housing IM001G

Housing IM001GC

Housing IM002GC

Order Information

Order Number

Description

IM003GC

PadPuls M2C, small battery (0,23Ah)

IM003GCB

PadPuls M2C, big battery (1,8Ah)

Both versions including configuration software MBCONF