Masterfamily W60
M-Bus Display / Logger / Level-Converter for 60 slaves
Display
-
Front-CPU with LCD and 4 navigation-keys shows important M-Bus meter data
-
Autosearch of meters with list generation
-
Passcode protection
-
Additionally usable as level-converter by the RS-232 interface
-
Firmware-update by RS-232
Logger
-
Same features as M-Bus Display and additional logging and data storage function
-
Historical meter data on LCD
-
Configuration and export of meter data by RS-232 direct link or modem
Level-Converter
-
Baudrates: 300 up to 9600 Baud
-
Overcurrent and short-circuit protection on the M-Bus
-
Echo cancellation and collision detection with break signalling
-
Displays for power, data transmission, max. bus current and overload in the screw-terminal room
The three members of the W60 Master Family are ideally suited for M-Bus installations with up to 60 meters.
The base model is the M-Bus Level Converter, which is standardly equipped with a RS232 and a RS485 interface. For remote read-out a PC with software is needed.
The M-Bus Display additionally allows real stand-alone operation with the integrated LCD and keypad. Therefore meter data can be displayed on-site with few keystrokes.
The third member of the W60 family, the M-Bus Logger, also automatically stores data at selectable times. The data memory can be exported to a PC or a laptop. Alternatively the use of a modem connection is possible.
Technical Data
Operating Voltage
230VAC (opt. 110VAC), 50/60Hz
Power Consumption
Power Input
12W
Temperature Range
0..55°C
M-Bus Voltage (without load)
39V (mark)
M-Bus Idle Current
Max. M-Bus Quiescent Current
M-Bus Current (C20)
M-Bus Current (C3)
M-Bus Quiescent Current
max. 90mA (60 unit loads)
Bus Impedance
M-Bus Standby Current
Overcurrent Threshold
140mA
Internal Bus Resistance
approx. 15 Ω
Bus Extension
Transmission Speed
300 .. 9600 Baud
Transmission Speed Optical
Bit Recovery
M-Bus Baud Rate
Galvanic Isolation
2.5kV (to the M-Bus)
Housing
light-grey plastic protection type IP52
H x W x D: 71 x 165 x 175 mm
wall mounted, sealable
CPU
LED Status Indicators
power, maximum load M-Bus, short circuit M-Bus
Control Panel
4 key plastic-foil keyboard (exceptional MR004W) LCD with 2 lines a. 16 columns, illuminated
Display
Memory
Security
Operating Controls
Interfaces
M-Bus, RS232, RS485
Screw Terminals
M-Bus (3-times), RS485, RS232 (GND, TXD, RXD) power supply (L1, N, E)
Terminals
RS232 as 9-pin. DSUB-socket
Connectors
Data Memory
minimum 2000 telegrams (just at MR004DL)
(shared to the number of meters)
Dimensions H x W x D
Protection
Manuals
Flyer
Software
Firmware WebGUI Version 1 (Broadway)
Firmware WebGUI Version 2 (HTML5)
Order Information
Order Number
Description
MR004FA
M-Bus Display (60 slaves)
MR004DL
M-Bus Logger
MR004W
M-Bus Level-Converter (wall)